Getting uniform pressure through the press

For discussions related to designing and making ski/snowboard-building equipment, such as presses, core profilers, edge benders, etc.

Moderators: Head Monkey, kelvin, bigKam, skidesmond, chrismp

gozaimaas
Posts: 663
Joined: Fri Feb 10, 2012 4:17 am
Location: Nagano Japan

Post by gozaimaas »

doughboyshredder wrote:Increasing the contact patch, by decreasing the gap between bottom and top mold is another good idea.
What would you say is the perfect gap from mould to mould? The diameter of the firehose will obviously have a big impact on this, I would think that if the fire hose was 4" diameter when fully inflated that as it approaches 2" in height you are seeing the maximum downward force applied.
So in that case if you had 4" hose, a 3" gap from mould to mould, a 1" cat track + the thickness of the board you should be close to ideal?
twizzstyle
Posts: 2204
Joined: Tue Mar 07, 2006 8:25 pm
Location: Kenmore, Wa USA

Post by twizzstyle »

The smaller the gap the better. There is no amount of inflation where you get "maximum force", it's all pressure. If the hose can only expand 1/2", it's still got the same pressure inside, so the resultant force will be the same (I'm leaving out contact area of course).

When my hose is fully inflated, it's taking up about two inches tops, it's an 8" wide hose un-inflated, I think I could probably get that down to 1". My press is also incredibly cramped though, so I have to keep things tight just to fit.
WhitePine
Posts: 141
Joined: Fri Oct 01, 2010 10:27 am

Post by WhitePine »

twizzstyle wrote:The smaller the gap the better. There is no amount of inflation where you get "maximum force", it's all pressure. If the hose can only expand 1/2", it's still got the same pressure inside, so the resultant force will be the same (I'm leaving out contact area of course).
Twizz - Truth.

COsurfer - You should read this thread. It should clarify the forces vs pressure you are seeing on the snowboard/ski.
http://www.skibuilders.com/phpBB2/viewt ... sc&start=0
Post Reply